BRANDED BUILDING MATERIAL SPECIFICATIONS :
( Price/Sq.ft Rs.1850 )
1. Steel – Pulkit ( ISI Brand Fe500 TMT bars )
2. Sand – M Sand
3. Cement – JSW
4. Bricks – Interlocking Mud Blocks
5. Hall/Room/Wall/Toilet/Parking Floor Tiles – Anuj
6. Kitchen Top granite : Dark Black /Red
7. Basement – Red Brick
8. Doors / Windows – Main Door Teak & Vengai Wooden Windows/UPVC
9. Frames & Shutters : Vengai Wooden/UPVC
10. Electrical Wires & Switches – Finolex & Philips Switches
11. Plumbing & Electricial Pipes- Astral
12. CP Fittings – Hindware
13. Kitchen Sink : KAG
14. Sanitaryware – Duravit
15. Wall Putty – Birla
16. Primer, Emulsion and Enamels : Berger
17. Waste Water and Water Line : 6 kg & 4 Kg Finolex/Star pipes.
18. Basement Filling Sand – Gravel
19. Overhead Tank – Sintex ( 1000 Liters Capacity )
INCLUSIONS :
1. Simple Masonry Elevation
2. Head Room
3. Water Proofing: Both interior & Exterior Walls
4. Hemp sacks for all stages for concrete curing process
5. Hall, Bed room & Kitchen loft and shelf works
6. Plan Drawing, Centre Line, Footing, Grade Beam, Plumbing and Electrical Drawings
7. The Column steel will be painted to prevent it from rusting
The following technical specifications will be given and explained in detail before concluding the construction agreement :
FOUNDATION :
Excavation
Sand Cuisine
Plain Cement Concrete
Isolated column footing Concrete
Pedestal Column Concrete
PLINTH BEAM :
Sand Cuisine
Plain Cement Concrete
Plinth Beam Size
BASEMENT:
Solid Block Work
Pedestal Column
Damp Proof Course
Sand cuisine
Plain Cement Concrete
SUPERSTRUCTURE :
RCC Columns
Outer 0’9” Wall
Inner0’4.5” Partition wall
RCC Sill Concrete
RCC Lintel Tie Beam
RCC Loft
RCC Sun Shade
Masonry Wardrobe
Roof Beam & Slab
Weathering Course
PARAPET WALL :
Inner Ceiling plastering
Inner Wall Plastering
Outer Wall Plastering
JOINERY :
Main Door
Doors and Window
Toilet Doors
GENERAL :
Elevation
Curing
Design & Size
ELECTRICAL AND PLUMBING WORK :
Indian water closet Unit
Western water closet Unit
Shower unit
Washbasin Unit
TECHNICAL SPECIFICATIONS :
Framed steel structure as per drawing reinforcement
Column Size : 0-9″ X 1′-3″ ,0-9″ X 1′-0″ & 0-9″ X 0-9″ (depend on spacing b/w column and no of floors)
Beam Size : 0-9″ X 1′-2″ & 0-9″ X 1′-0″ (depend on spacing b/w column)
Steel used in column: Main rod- 12 mm (dia) and Stirrups-10 mm (dia) at spacing of 8 inches
Plinth Beam Steel : Main rod- 10 mm (dia) and Stirrups-8 mm (dia) at spacing of 8 inches
Lintel Beam Steel : Main rod-10 mm & 8 mm (dia) and Stirrups-8mm(dia) at spacing of 8 inches
Steel used in Roofing : 12 mm, 10 mm and 8 mm at spacing of 7 to 8 inches
Height of the basement 3 feet
Depth of the foundation 6 feet
Size of the footing 4’6*4’6
Roof Height 10 feet
Roof Thickness Of Slab : 5 inches
Sunshades Steel : Main & Distributors- 8 mm dia
Plinth Beam Concrete Mix : M20 ( 1 : 1.5 : 3 = Cement : Sand : Stone )
Brick Works Concrete Mix : 1 : 5 ( Cement : Sand )
Nominal Cover to reinforcement:- Footing-50mm: Column-40mm: Plinth & Roof Beam -25mm and Roof Slab-20mm
DURATION :
4-6 months
We are confident that you will find our proposal eminently suitable since we pack our
Services with sincerity and work with your aim as our goal.
We offer to meet you at your convenience and to offer any clarification that you may like
to seek.
Contact us at jkbuiltron@gmail.com to get your Dream home, Commercial Building
Apartments & Villa Project.
For JK Builtron
D. Arul Raj (Project Head)
Mb : 9514144157
WhatsApp : 8695844864